Excessive occupational noise is more than just a comfort issue. It’s a health and safety risk governed by strict legislative requirements.
In Western Australia, employers must provide audiometric testing if their team relies on hearing protection to control exposures above legal thresholds. At ENVSS, we help you meet these obligations through onsite mobile hearing tests, detailed assessments and clear reporting tailored to your workforce.
WorkCover WA Audiometric Testing requires certain employers to provide audiometric testing for their employees who are exposed to noise in the workplace. Audiometric testing is a type of hearing test that measures a person’s ability to hear sounds at different frequencies and volumes.
Employers in Western Australia who are required to provide audiometric testing to their employees must do so in accordance with WorkCover WA’s Occupational Safety and Health Regulations 1996. These regulations require employers to:
WorkCover WA provides additional guidance on audiometric testing and other occupational health and safety requirements on its website. Employers who are unsure whether they need to provide audiometric testing or who have questions about how to comply with WorkCover WA’s regulations should consult with a qualified occupational health and safety professional or contact WorkCover WA directly for guidance.
In Western Australia, businesses must comply with four important regulatory items: Regulation 58, AS/NZS 1269.4 protocol, Code of Practice: Managing noise and preventing hearing loss at work, Work Health and Safety (General) Regulations 2022, r. 58 (1A)(2) and the Privacy Act 1988.
According to the general regulations: “The person conducting the business or undertaking who provides the personal protective equipment as a control measure must provide audiometric testing for the worker –
(a) within 3 months of the worker commencing the work; and
(b) in any event, at least every 2 years.”
That applies when workers are frequently required to use PPE as a control measure for noise that exceeds LAeq,8h of 85 dB(A) or LPeak 140 dB(C)
Other requirements in these standards can be long and complex, but some of your key responsibilities are:
Fostering communication between workers and health and safety representatives about audiometric testing
Providing appropriate and effective protective equipment
Keeping employee data and results confidential
For more detailed information, please get in touch with our team.
Often, clients approach us in situations where testing is required by the code of practice. Those include:
Workers are exposed to any of the ototoxic substances listed in Appendix 2 of the COP
Noise with LAeq,8h greater than 80 dB(A) or LC,Peak greater than 135 dB(C)
ENVSS’ mobile audiometric testing booths can be sent across WA. Our testing is carried out by an accredited noise officer, who will test workers’ hearing using a Pure Tone Air Conduction threshold test. We then conduct audiometric tests using a currently calibrated Oscilla Audiometer – SM930.
Our testing utilises Telephonic TDH-39 earphones housed within 3M Peltor enclosures, which are specifically designed for audiometric testing.
If you are unsure about the level of noise in your workplace, ENVSS can assist by conducting a detailed occupational noise survey in accordance with Australian Standards and Codes of Practice. Our surveys:
Identify significant noise sources
Identify possible ototoxic substances
Provide PPE advice likely to be exposed to excessive noise
After a survey, our team will suggest one of two types of audiometric testing:
Formerly known as a ‘baseline test’, a reference test is exactly that – a baseline assessment. It must be conducted within the first 3 months of a worker’s employment and looks to determine whether their hearing meets National Acoustic Laboratory (NAL80) criteria and establish a benchmark for future comparisons. Reference tests follow this procedure:
The worker completes a 16-hour period of quiet pre-test
They provide personal details about occupation, contact information and hearing protection usage
Our team conduct testing as described above
The results are stored as a reference point for identifying any future changes to hearing function
A second reference test is required after 10 years of if a permanent hearing threshold shift is found and medically confirmed. With a reference test, you can monitor long-term auditory health and promote simplified compliance with occupational health standards.
Previously called ‘subsequent tests’, there are two kinds of monitoring tests:
Initial
Initial monitoring tests are a routine-follow up to detect any possible changes since the reference test. It is typically conducted every two years or when concerns arise. They look to identify work-related hearing threshold shifts such as the onset of tinnitus or cross hearing. To realistically assess exposure impacts, we conduct these tests at least half-way through a worker’s shift.
Before testing, workers must provide details about their noise exposure and any new symptoms, such as tinnitus or recent earwax removal. We then compare results gainst the reference test to detect early signs of damage. Workers may choose not to share results with their employer but if any concerns are flagged, a second monitoring test will be arranged.
Second
The second monitoring test is a follow up on the initial assessment, conducted to confirm whether any identified shift is temporary or permanent. It needs to occur within 30 days of the initial test and following a 16-hour quiet period. Results are closely compared with both the reference and initial monitoring tests and if a significant and permanent shift is confirmed, it may trigger the need for a new reference test and medical review.
Like previous tests, the worker is asked to provide updated personal details and disclose any recent changes in symptoms or medical procedures affecting hearing. The results support compliance with WorkCover WA and occupational health requirements.
All workers who have never had a ‘Baseline’ test who begin working for the first time in a ‘prescribed workplace’ must have a ‘Baseline’ test within twelve months of starting the job.
It is the employer’s responsibility to arrange and pay for baseline and subsequent tests and notify workers of the time and date of the test. It is the responsibility of both the worker and the employer to ensure that you are not exposed to more than 80dB(A) for 16 hours immediately preceding the test. This is approximately equal to the noise of a vacuum cleaner one metre away.
All workers continuing employment in a ‘prescribed workplace’ may request a hearing test every year, for which the employer is required to pay. The request should be in writing and the employer must arrange the test within one month of the request.
When a worker leaves a job, they are not required to have an exit test, but it is recommended that the employer arrange this.
If a worker has undergone a test within 3 months of starting a new job, that test may be taken as occurring at the time the worker started the new job and the worker would not need to be re-tested. This is providing the test was conducted in accordance with WorkCover WA testing procedures.
Workers who are retiring should have a hearing test at the time they leave their job unless they have had a test within 3 months of leaving the job.
If a retired worker returns to work in a ‘prescribed workplace,’ they must have a hearing test within three months of starting the job.
If a hearing threshold shift has been detected in a worker or new tinnitus reported, the following actions are recommended to determine the cause of the shift. Responsible managers should:
1. Identify changes in exposure to noise/ototoxic hazards and reduce if practicable
2. Review hearing protection selection and PPE for ototoxic hazards
3. Ensure employee can fit PPE correctly and wears it for duration of exposure;
4. Refer the worker for audiological counselling if threshold shift is permanent or experiencing new tinnitus
5. Conduct a new reference test if the shift is permanent.
With proper monitoring, testing and control measures, workplace hearing loss is certainly preventable.
ENVSS supports you through every stage of audiometric testing: from identifying hazardous noise through to follow ups. Our accredited noise officers use all relevant regulations to guide their work, giving you the confidence that ENVSS will help you stay compliant.
For more information or to book a mobile hearing testing session, please get in touch.
All testing booths must be issued with a Certificate of Approval from WorkCover WA which will indicate the measured ambient noise levels across applicable octave band centre frequencies. This must not exceed the maximum permissible noise levels of the earphone/cushion combination, or the results obtained from tests conducted in these testing booths/environments will not be accepted by WorkCover WA for the purposes of the legislation.
To be eligible for approval, a testing booth must be evaluated by a qualified noise assessor or persons who are eligible for full membership of the Australian Acoustical Society. The testing booth must comply with the Australian Standard AS/NZS 1269.4:2014 for the type of earphone/cushion enclosure attached to the audiometer.
A list of approved noise assessors is available from DMIRS. The noise assessor must provide the booth owner with a completed Form 408. This form must then be submitted to WorkCover WA before an approval certificate is issued.
For full audiological assessments at either the baseline or subsequent levels, the requirement for bone conduction assessment will almost certainly mean that the testing environment must meet the greatest level of attenuation required in the above standards.

Occupational hygiene entails identifying, evaluating, and managing workplace environmental risks to health. Our services cater to diverse needs, crafting solutions for complex hygiene and safety challenges. Our expert staff collaborates with you to implement effective hygiene management systems, crucial for meeting site and legal standards.

We are a Licensed Asbestos Assessor (LAA) and provide hazardous material management to building owners, property developers and facility managers to meet specific client requirements including identification and risk assessment of hazardous materials, development of detailed hazardous material management plans and supervision of hazardous material remediation works.

Monitoring services are tailored to your needs, ranging from ENVSS staff attended monitoring to autonomous stations with remote telemetry and alerts. You can access real-time data, make informed decisions, and generate reports via our Client Portal. We understand industry demand and meet client expectations by building our equipment to be flexible, mobile, efficient, accurate and robust.

Our noise and vibration services cover both regulatory compliance and occupational health, with services ranging from noise monitoring, blast monitoring, earplug fit testing, human vibration testing and more. Our monitoring devices are set and forget with remote software, allowing us to capture a wealth of data spread over a timeline of your choosing.
"*" indicates required fields